Connect two lock
Jumper posion in 2-3
4. System Wiring and Connecons
4.1 Basic Connecon
4.2 Electric Lock Connecon
-
+
AC~
Monitor
DPS PS4
L1 L2 PL S1+ S2+ S-
EB
*
LOCK
BUS PL S1+ S2+ S-
LOCK
2
nd
1
ST
2
nd
EB
*
1
ST
1 2 3
EB
*
LOCK
BUS PL S1+ S2+ S-
Connect one lock
Jumper posion in 2-3
1 2 3
Note:
1. Only applicable to the power on to unlock type of electronic locks.
2. The door lock is limited to 12V, and holding current must be less than 250mA.
3. The door lock control is not med from Exit Buon(EB).
4. The Unlock Mode Parameter of Monitor must be set to 0 (by default).
4.2.1 Door Lock Controlled by Internal Power
4.3 Electromagnec Lock Connecon
Note:
1. Only applicable to the power off to unlock type of electronic locks.
2. The door lock is limited to 12V, and holding current must be less than 250mA.
3. The door lock control is not med from Exit Buon(EB).
4. The Unlock Mode Parameter of Monitor must be set to 0 (by default).
4.3.1 Door Lock Controlled by Internal Power
Connect one lock
Jumper posion in 2-3
1 2 3
EB
*
LOCK
BUS PL S1+ S2+ S-
Normally closed
Connect two lock
Jumper posion in 2-3
EB
*
LOCK
LOCK
2
nd
1
ST
2
nd
EB
*
1
ST
1 2 3
BUS PL S1+ S2+ S-
Note:
1. The external power supply must be used according to the lock.
2. The inside relay contact is restricted to AC or DC 24V/3A.
3. The jumper must be taken off before connecng.
4. Setup the Unlock Mode of Monitor for different lock types.
• Power-on-to-unlock type:Unlock Mode=0 (by default)
• Power-off-to-unlock type:Unlock Mode=1
4.3.2 Door Lock Controlled by Dry Contact
Connect two lock
Take off the Jumper
1 2 3
BUS PL S1+ S2+ S-
LOCK
LOCK
POWER
SUPPLY
LOCK
BUS PL S1+ S2+ S-
POWER
SUPPLY
Connect one lock
Take off the Jumper
1 2 3
-7--6-